Gas Leak Location > Detection Equipment > EX-TEC GM 4

SlideDownload Brochure

EX-TEC GM 4

EX-TEC GM 4 Gas Detection EquipmentEX-TEC GM 4 Gas Detection EquipmentEX-TEC GM 4 Gas Detection Equipment

EX-TEC GM 4

Click on any image to enlarge
EX-TEC GM 4 Gas Detection Equipment

Gas warning and gas measuring instrument for detecting toxic gases,flammable gases, and oxygen

The ideal measuring instrument for gas and water suppliers, fire-brigades, sewage plants, landfills, biological gas plants and chemical industry.

Applications:

  • leak detection at pipes
  • monitoring environmental air
  • gas measuring to monitor chemical or biological processes

EX-TEC GM 4 FEATURES

EX-TEC GM 4 Gas Detection Equipment
  • modular instrument concept, basic device without pump (diffusion device) or with built-in pump
  • electro-chemical sensors
  • interchangeable sensors by the operator
  • all commercial Mignon accummulators or batteries may be used for power supply
  • micro-processor controlled
  • large, illuminated LCD
  • self-test when switched-on
  • simple handling by three keys
  • internal data storage (PC evaluation possible)
  • visual and audible alarms
  • adjustable thresholds
  • temperature compensated sensors
  • user menu
  • function menu for individal instrument configuration (PIN-Code protected)
  • adjustable test gas concentrations

 

Sensors:


  • Passive protection:
  • EC-type-examination certificate in accordance with ATEX 100a, guideline 94/9/EG
  • Certificate No.: TÜV 01 ATEX 1657
  • Identification: EX-Symbol II 2 G EEx de ib IIB T4
  • Active protection:
  • Function safety test in mode "warning" at "Deutsche Montan Technologie GmbH"
  • Test report: PFG-Nr.:413 007 02P

Sensor operation/measuring range


- Measuring range Response time t90 Durability
- carbon monoxide (CO) 0 ... 500 ppm < 30 s 2-3 years
- hydrogen (H2) 0 ... 10.000 ppm < 70 s 1-2 years
- hydrogen sulphide (H2S) 0 ... 100 ppm < 30 s 2-3 years
- hydrogen sulphide (H2S) 0 ... 2.000 ppm < 90 s 2 years
- ammonia (NH3) 0 ... 100 ppm < 60 s 1-2 years
- oxygen (O2) 0 ... 25 vol.% < 30 s 2 years
- hydrochloric acid (HCI) 0 ... 30 ppm < 70 s 1-2 years

Accessories

EX-TEC GM 4 Gas Detection Equipment
  • GasIS (PC evaluation software) for documentation of measurements
  • charging technique for 12 V, 24 V or 100-240 V
  • leather bag
  • various probe systems
  • test set and test gases
  • case

Technologies for leak detection.

HAVE YOU SEEN

Flammable gas warning, gas concentration measuring instrument
Multi gas monitor for up to six gases simultaneously
IR gas detector for newtork survey